Air conditioner

Air conditioning floor ceiling of 36,000 btu

Luis
Luis
5
hace 6 años
hace 6 años
Good afternoon my people... I have a problem with a 3 ton roof floor air the problem is that I put a little gas and the price was set at 40 psi then I put more gas and put in 70 psi then the high pipe becomes cold and the Low pipe does not get cold then the briker shoots at 15 minutes and everything goes out ... please if you can help me with this problem. ..
cris2260ts
hace 6 años

good, is the team new? type of gas? other than that they have put another replacement gas and in case it is a liquid phase charge did you respect this type of charge?

Responder
Luis
Luis
5
hace 6 años

The type of gas is R22 but the high pipe is as if it were the low pipe ... the equipment starts to cool a chin but then shuts off after 15 minutes ... where the high pipe has to be hot and the pipe Low cold ... 15 minutes after the compressor entered. .the breiker shoots and then everything goes out

Responder
Roy Velasquez
hace 6 años
hace 6 años
Good, you must first check the filter drier, it may be clogged. We will proceed like this: with the OFF air you connect the manometer to the high clock you connect it to the high valve and then turn ON the air conditioner and connect the low clock and wait for a while and observe the 2 pressures and locate the filter dryer and you feel by hand its temperature on the inlet and outlet of the dryer filter and see if there is any temperature difference and this operation is done several times in a period of time and after a while you observe a temperature difference between the entrance and exit of the filter, that is indicative that it is clogged. check the entire pipeline high and that it is not bent or broken. check that the 2 keys of the load valves are open (Allen keys). make sure that this condensing unit is an expansion in the condenser or an expansion in the evaporator. if the expansion is in the evaporator there the high pipe if it must be hot. if the expansion is in the condenser, the thin pipe should be cold and in this case it would be called a liquid or pre-expanded pipe. That fault you indicate is due to an obstruction in the high pressure line and may be due to the causes: clogged filter, moisture, bent pipe or closed or locked expansion valve. Friend any questions you comment here.
Luis
Luis
5
hace 6 años

Thank you very much friend

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis