INVERTER 1 TON MARK FRIKKO IN DISPLEY SAMPLE FAILURE E9

Jose  Emilio
hace 6 años
hace 6 años
Hello I have a FRIKKO minisplit of 12,000 btu inverter cold / heat when I turn it on for 2 minutes and turns off the compressor and condenser fan at 5 min. it starts again and cools but after 2 minutes the fan and compressor turn off again and the display shows error E9. THANK YOU VERY MUCH FOR YOUR HELP . MODEL FKEILJ122H
Clima Bueno
Clima Bueno
3.681
hace 6 años
hace 6 años
I do not know the error code of that brand, but in principle I would tell you to control the thermal sensors. regards
Jose  Emilio
hace 6 años

Thank you very much Alberto, I'm going to change the well and ambient sensors and I'll tell you how it was

Responder
Roy Velasquez
hace 6 años
hace 6 años
Good morning Mr. Jose Emilio. I ask you, when you start to work the fan motor of the condensing unit you see the blade turning strongly? or getting enough air? you should check the capacitor of the capacitor motor, for that you must have a capacitor or disconnect it from the card and take it to a spare parts sale or a technician in electronics to check it, NOTE: to do that work you must disconnect the electric power and DO NOT touch the card on the back where the welds are and be very careful not to touch the back where the 3 battery-type capacitors are soldered, since they accumulate high voltage. Another question ... have you done maintenance service to the air? washing coils with water under pressure. check if the coil of the condensing unit is dirty or covered and if so proceed to wash it, by logical covers or protect the motor and the cards very well. another ... check the Voltage, measure it with a tester and see if it is in the ranges recommended for air conditioning. Summing up what you should do and check ... (1) check the condensing coil, which is clean. wash it with water under pressure. (2) slow capacitor motor ... check and measure capacitor capacitor motor, it is usually 2.5 microfarad. (3) Measure the voltage at the socket or breaker and see if it is the right one. low or high voltage. Friend José Emilio, any questions comment here.
Jose  Emilio
hace 6 años

I AM VERY ESTIMATE YOUR VERY COMPLETE ANSWER FOR CERTAINLY AND EFFECTIVELY IF I HAVE NOTED THAT THE CONDENSER FAN IS NOT RUNNING AS IT DOED BEFORE, AND YOU ARE ENOUGHLY THANK YOU WHAT YOU THINK ABOUT THE BATTERY TYPE CAPACITORS FOR THE ACCUMULATING ENERGY AND THE RISK OF SOME DOWNLOAD I BELIEVE THAT THE PROBLEM IS IN THE CAPACITOR OF THE FAN MOTOR. MAINTENANCE IF IT IS MADE. THANK YOU VERY MUCH FOR YOUR ANSWER .

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis