fabian66
hace 6 años
hace 6 años
Good afternoon I repair people, my query is the following, air fired from 3000 frig, R22, we told the owner of the house that the previous technician could not load more than 30 PSI in temperate ambient conditions, the air did not cool, changed the robins and nothing, when I called I measured the pressure that pulls the engine in the high-rotor and after 3 minutes did not rise more than 350 PSI, I assumed it was the engine since the team has its good years I change the engine for another one of the same conditions but a newer model than the one I had, I empty it and when I charge gas I always work in vacuum, I could not pass it from 0 lbs, I loaded gas and it went empty, I tried another one of 4500 Frigorías (only to prove) and I did the same, the system is uncovered since I could measure the engine pressure before removing it, what will be the cause ?, thanks for the help [/size]
omorma
omorma
15.708
hace 6 años
hace 6 años
Hi, how are you, first check that there is a double interconnect pipe and when you make a compressor change you have to clean both internal circuits and preferably replace the filter and capillary so that this happens to you not happening now and possibly changed the compressor and that was not the problem but if the capillary and filter clogged, suggestion: remove the compressor clean the whole circuit with 141b and then nitrogen pressurize solder to control solder loose nitrogen performs vacuum and load by weight, greetings.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis