⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Air conditioner

LG 110v Compressor Capacitor

Josguiber Garcia
hace 6 años
hace 6 años
Hello friends, my question is which capacitor uses an LG 110v drive? since I went to check an air and I find that it has a capacitor of 60 mf that a technician I put and I touch but it is hot! I have doubts because I do not know how many mf uses that brand of window air. The fan was placed one of 6 mf I also have doubts. someone to help me with the right thing please.
luiscataño
luiscataño
1.045
hace 6 años

It is more explicit, air capacity, and / or reference of the compressor, and fan

Responder
Josguiber Garcia
hace 6 años

12,000 btu LG 110v the fan does not have the specifications

Responder
TECNICOSREFRIGERACION
hace 6 años
hace 6 años
Hi friend the capacitors are according to the manufacturer. Provide more information. . as the model of the compressor and the btu or frigorías
luiscataño
luiscataño
1.045
hace 6 años
hace 6 años
So we all guess, the most logical is send the reference of the compressor, for me most logical would be one between 35 and 45 uf for 2250 volts But send us the reference of the compressor and we will be more effective
Josguiber Garcia
hace 6 años

Friend I do not understand that anything else I can tell you about the compressor, what is it is that is 110v LG brand 12.000 btu window

Responder
luiscataño
luiscataño
1.045
hace 6 años

all those engines have a number look for it, with which you look for the characteristics of each of them, place a 40uf

Responder
luiscataño
luiscataño
1.045
hace 6 años

I meant 40 uf 250 volts

Responder
cubitomanu
hace 6 años
hace 6 años
Hi Josguiber ... the compressor has a tag attached, we are requesting information from that tag. Conditioners of the same brand, voltage and refrigeration capacity may have different compressor models. Without specific data the answers are just riddles. Greetings.
TECNICOSREFRIGERACION
hace 6 años
hace 6 años
The most common for these equipment is 40 microfarads but without the compressor characteristics the response will be uncertain. When we do not have labels we can check the following way to place a capacitor that is considered adequate and measure the consumption if the consumption is the one indicated by the equipment Then this is appropriate if you place a very small capacitor the equipment does not turn on or turn on with little power and when you place a very large capacitor this can raise the amperage to almost double
TECNICOSREFRIGERACION
hace 6 años
hace 6 años
The most common for these equipment is 40 microfarads but without the compressor characteristics the response will be uncertain. When we do not have labels we can check the following way to place a capacitor that is considered adequate and measure the consumption if the consumption is the one indicated by the equipment Then this is appropriate if you place a very small capacitor the equipment does not turn on or turn on with little power and when you place a very large capacitor this can raise the amperage to almost double
jose antonio
hace 6 años
hace 6 años
hi friend how hot it is normal you can check on the compressor label if it is 110v the 60uf capacitor this well i ran into several of 110 and they bring 60uf since they usually come with capacitance values ​​higher than those of 220v, i usually I find that they take 40uf to 50 uf for saver if it is working correctly check the capacitor with a capacimeter you should give 60uf if you do not have the device you can check the amperage of the compressor in gear should be used with the board normally consume 10Amper. The 110v fan normally occupy 3 to 5 Czech same on the motor label I hope you serve the inf.
redk141
redk141
44
hace 6 años
hace 6 años
good afternoon friend if the compressor is 12000 btu the capacitor can be changed by one of 50 max 55 uf but send the specifications of the plate with respect to the hot is normal the air 110v the compressors reheat a little more than the 220v
Josguiber Garcia
hace 6 años
hace 6 años
Hello friends, the specifications of the board is: QK164CBF RLA: 56 115V LG brand 12,000 btu window
wuilmen
wuilmen
97
hace 6 años
hace 6 años
Good evening, friend that compressor uses 50mf capacitor.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis