⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Fixed telephones

Ignition fault centers panasonic kx ns 500

Anibal Zabala
hace 5 años
hace 5 años
HELLO I HAVE A PANASONIC KX NS 500 CENTER INSTALLED WHICH WAS PERFECTLY UNTIL A DAY DOWN AND NO LIGHTED. IF YOU CAN HELP ME TO MAKE A DIAGNOSIS OF THE PROBLEM THANK YOU
Guillermo Colín Castillo
hace 5 años
hace 5 años
Hello Hello It seems that the source is damaged. The repair of the source is more or less expensive as in 3mil or 4mil pesos Panasonic has the new equipment on sale $ 14,999.00, visit www. KX-NS500. com Also on that page you can request support, repair they lend you a team while they repair yours and even change the equipment to a new one as a technological update at a very good price. I hope the information serves you Greetings and luck
Anibal Zabala
hace 5 años

a ok thank you very much for your help now I will follow your advice

Responder
LUIS R FARIAS
hace 5 años
hace 5 años
I would like you to give me more information, whether or not the panel has the LEDs of the modules on or not If they are turned off the source will be damaged. Now if the LEDs are on, you may have to reset it following a shutdown procedure, place the switch on initialize, turn on the equipment and when start the led to flash place it in normal
Anibal Zabala
hace 5 años

Hello thank you very much for your help I explain in detail the master cabinet does not turn on any LED and sometimes it turns on but the red LED but for it to turn on and put on the red LED they spend approximately 24 hours and it lasts very little time working and then it turns off completely and does not turn on any LED the central also has another cabinet which the status LED blinks green normally I hope that with this explanation you can help me a lot thanks

Responder
LUIS R FARIAS
hace 5 años

Anibal in the main cabinet there is an initial and normal interuptor, turn off the cabinets you place the interuptor in initialize
Then you turn on the device and when it starts to flash you put it on normal, and you will see that your device starts, because if you say
that the LED turns red, indicating that the control panel detects an integral fault, in the mmc

Responder
Anibal Zabala
hace 5 años
hace 5 años
Hello sorry for the delay I wanted to let you know that the problem was the power supply had a couple of components burned thank you very much for the collaboration

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis