⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Fixed telephones

Nexus Selenia 8.24 Pre-loan programming and NEXOCDX program

Robocardo
hace 6 años
hace 6 años
I have two queries: 1. When programming the pre-mixer I find that after recording the messages and activating them and listening to them correctly when I enter through the external lines, I do not carry out the programmed call diversion. In my case, the derivation of calls corresponds to two digits, 1 and 2. 1 must refer to inmate 100 2 must refer to inmate 102 I program or try to do it using this command use 9 # 953 1 3 3 3 3 3 3 3 3 to enable the 8 external lines although it has 2. Then I will detect which ones to enable. Use 9 # 954 1 01 01 1 1 to enable predator 1 with daytime message 01 and nighttime idem, free DISA line and branch Idem with predator 2 9 # 954 2 01 01 1 1 Here comes the subject but maybe I forgot something out of this 9 # 955 1 01 1 2100 should be the derivation for digit 1 to internal 100 in predator 1 9 # 955 1 01 1 2102 should be the derivation for digit 2 to internal 102 in predator 1 for the preat it is the same except the change corresponds. Well when trying everything goes to the 100 inmate what makes me think that there is a higher level programming that is sabotaging the predator? 2. Regarding the NexoCDX Software just know if it is attainable or you have to contact the supplier and buy it.
mantonegro
mantonegro
1.137
hace 6 años

In the part where programs that sound 100 and 102 only change the intern number, some of the previous digits in 102 should be a 2, indicating that for that option (2), go to 102. In general, when you give options 1, 2, 3 etc., is usually identified as DISA by Menu or automatic assistant. This should be active. In Nexus as far as I know, the option must be checked at the end of the message, not during it, because it does not take it and if at the end of the message it does not detect any incoming tone (1 or 2 or 3, etc.), it derives to 100 . Cheers.

Responder
Robocardo
hace 6 años

Ok thanks i will try

Responder
cargus
cargus
787
hace 6 años
hace 6 años
http://www.centralesnexo.com.ar/
Robocardo
hace 6 años
hace 6 años
Well finally, the people of Santa Santa Fe Central gave me the answer, courtesy of the Technical Service. My mistake was this i used 9 # 953 1 3 3 3 3 3 3 3 3 and the configuration must be 9 # 953 1 5 5 5 5 5 5 5 5 DISA FAX predator in daytime
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis