totoxxxx
hace 5 años
hace 5 años
Hello people, I tell you, I have the new pipes in thermofusion of 3/4 of the lowering of the tank, in the bathroom it is perfect the theme is in the kitchen and the thermos that a trickle comes to me ... or I may lack pressure, that has some obstruction that I have hit a pipe badly (I'm baked) or that has many turns (baked with potatoes) ... which I doubt of all and I do not want to do macana or whatever I hit in the bathroom I did not have no pressure or obstruction problem ... if it were a pressure problem I suppose that with a pump I could solve it but is there any method of checking without obstruction without breaking? because I have everything painted and placed the ceramics ... but what do they tell me? there I send a drawing as is the route .... FIRST PHOTO: view of the tank with the path of the pipe that goes through the outside of the wall, that is to say, it is attached to it with hooks because it is the neighbor's yard. the one that goes down is the one that goes to the bathroom and the one that goes to the left goes to the dining room. PHOTOS 2 seen from inside the dining room, the * red is the pipe that comes from the tank seen in the previous photo. [Img] https://cdn.yoreparo.com/uploads/imagen_post/0002/06/8cc84e8d7f33bee6a4d7e46423295f470ee4d122.jpeg [/img]
xuso3558
xuso3558
291
hace 5 años
hace 5 años
Hello, if they are new tubes, I do not believe in an obstruction, perhaps in any of the glued it has been bad and obstructs the passage, for now you have many elbows, which are sure to be 90º, they should be 45º, brake less to the water, I refer your drawing to see how you should have done, do not take criticism please, you must always look for the straightest path possible, for the tiles, if you can work on the other side of the wall you will not have to break almost nothing, but unless you have adequate material to be able to put in the tube to see if it is clean, you will have no choice but to open, either to search, or to put a new tube, luck, greetings
xuso3558
xuso3558
291
hace 5 años

Wow, it doesn't let me load the drawing, well I tell you from the cut-off key, a direct pipe down to the socket, that is to say diagonally through the wall.

Responder
totoxxxx
hace 5 años

Hello, will an Android Borescope Endoscope Pc Usb Inspection 5.5mm 1m be used to look inside the pipes? I can't break the other side ...

Responder
xuso3558
xuso3558
291
hace 5 años

Wow, you are more up to date with new technologies than me, I did not think about that, well, at first it will work for you, but keep in mind that when you reach an elbow I do not think you can pass it, with the risk of being attacked and even lose more, look to break almost nothing, I would do at the point that you choose you will have to open, to make a shot with a new tube, thus removing the old one from the wall, of course, that new tube will have to be put on the surface , that is to say, well attached to the ceiling, looking to go down a corner and horizontally to the heater.

Responder
Ricardo Ab.
Ricardo Ab.
5.181
hace 5 años

Hello, I suppose you will refer to curves at 90 ° and not elbows at 45 °. With elbows at 45 ° the installation would be diagonal.

Responder
Ricardo Ab.
Ricardo Ab.
5.181
hace 5 años
hace 5 años
Hi Can the cutting key be disassembled? Or is it thermofusion? You could disassemble the key and see if there comes good pressure. When you did the mergers, did you consider the temperature and depth of the joint? They are the two common causes of obstructions especially in the elbows. If you go over temperature, more material is dragged than necessary and if the depth is not taken into account, the same thing happens, a very restrictive ring is formed. If there is little flow to the cutting key, well the obstruction would be in one of the four previous elbows. The external part is easier, you can cut and join again with a cup.
totoxxxx
hace 5 años

Hi Ricardo, it was the key cut at the end that had disarmed the rod less badly that I did not break anything .... thanks

Responder
Ricardo Ab.
Ricardo Ab.
5.181
hace 5 años

Was the stem disassembled? Could you expand, because it is very rare? Either way, I'm glad I could help! Greetings and Happy Holidays!

Responder
servimat1
servimat1
138.835
hace 5 años
hace 5 años
Hi. Apparently there would be some obstruction at some point. In the 1/2 "exit is where you have the problem? Regards
totoxxxx
hace 5 años

if I open the one of 1/2 comes out a splash and the one of 3/4 nothing, if I close it the one of 3/4 comes out a splash ....

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis