How much water in a tank do you recommend?

elguardian_1978
hace 5 años
hace 5 años
Hello I ask them a question, I have low water pressure, I live in a PH and we always had the same problem, what they recommended was to place a 200LTRS or 500LTRS water tank, with a lift pump because I don't have a terrace. Is that recommendation okay? We are 2 people, we have water, but at certain times due to the use of other neighbors we are affected, the others if they have a terrace and their water tank. The tank would go at a height of about 5 mtrs from the ground. There are several pumps, such as peripherals, elevators, centrifuges, pressurizers etcc, I really do not understand much what each one is for, I know that they give more water pressure to fill the tank, but I have my doubts. Thank you
elektomaq
elektomaq
62.202
hace 5 años
hace 5 años
The capacity of the tank will depend on the amount of water they use between filling periods, 200 to 1000 l may be enough .... we cannot tell you that and it has no relation to pressure, it is according to what you If you need, what should be fixed is that if they use between 200 and 300 l per day they do not buy one of 300 l because many days they can run out of water, always buy a little more (example of 500 l) in order to ensure some autonomy. .. to raise water to a tank the pump can be a lift, among them is the peripheral and the centrifuge, what changes in them is the type of impeller that the centrifuge has the best performance. Then there are the intelligent type whose advantage is that they do not require an electrical control circuit for operation Then, to achieve greater pressure on the lines of the house, in case the one that is not enough, you need a pressurizer that goes at the base of the tank if the tank is 5 m high from the floor of your apartment the pressure has to be acceptable unless there are clogged pipes or air in them regards
mariotti luis marcos
hace 5 años
hace 5 años
Hello: if you place a tank that is between 700 and 800 liters with the tank at 5 meters high you will have pressure. But it will be less than with direct water the advantage of the tank is that you have the water reserve, the pressure will be less but stable it will not fluctuate another advantage is that the pipes remain open, it is good to extend the life of the water heater such as hot water tanks etc. Look carefully at the network pressure. the distributor should guarantee a pressure of between 1.5 and 2 kg cm2 would reach a height of 15 or 20 meters, it is not necessary to place a lift pump if at any time during the day the network pressure generally falls at night when consumption falls, the pressure will be normalize and the tank would fill without problems any doubt comments greetings,
servimat1
servimat1
138.835
hace 5 años
hace 5 años
Hi. Where does the current water they use come from? Instead of a tank, they may only need an automatic pressurizing pump in the water line. If you are going to place a tank (independent of its capacity) it would be necessary to verify if the current pressure will reach its new height. Regards
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis