hello good day, I have a water tank of 95 liters, the water tank is 6 meters high and the thermos is 2.5 meters from the floor or there is a difference of 4.5 meters between them. The plumber connected me with flexible from the water outlet to the hot water tank and both fexibles have in turn another extension of another flexible because the distance did not reach but I have heard that it does not connect with flexible but with a pipe is it? Can it affect the water pressure? Thank you Attached photo Screenshot_20180210-065240.png [1.74MB]
Diegomar
Diegomar
214
hace 5 años

There I uploaded a photo of the current connection to see how it is with the flexible. And the height to the entrances and exits. Should fusion then?

Responder
Ricardo Ab.
Ricardo Ab.
5.181
hace 5 años

Hi. It seems that the plumber didn't really want to work.

Responder
Diegomar
Diegomar
214
hace 5 años

Hahaha as is

Responder
Javierorsi
hace 5 años
hace 5 años
Hi. To start the height of the water heater does not affect, the pressure is the height of the tank with respect to the bobbins. The second point is that the more pieces the less pressure and in the case of the flexible ones in some cases it aggravates it because the inner diameter does not correspond to the diameter of the thread (especially in flexible meshes).
Diegomar
Diegomar
214
hace 5 años

Thank you very much Javier and what do you recommend me to put in place of the flexible meshes?

Responder
Javierorsi
hace 5 años

What kind of pipe do you have? Can you upload a photo?

Responder
Ricardo Ab.
Ricardo Ab.
5.181
hace 5 años
hace 5 años
Hello The connections are made with pipe and double union to be able to take out and purge (among other things). _-_ Manual_Termotanques_Saiar Linea_Gas_1_1_.pdf [449.69kb] Regards
Diegomar
Diegomar
214
hace 5 años

What type of pipe do you recommend?

Responder
Diegomar
Diegomar
214
hace 5 años

The output is 3/4 of fusion and from there come the flexible ones to the top of the thermos

Responder
Ricardo Ab.
Ricardo Ab.
5.181
hace 5 años

You can do it with thermofusion or threaded. Nowadays the best thing is plastic, there are double and triple layers, different brands all good (or almost all)
Regards

Responder
Ricardo Ab.
Ricardo Ab.
5.181
hace 5 años

I add an attachment so you have an idea of how it is mounted, no matter the brand, in general they all connect the same. The only thing that can vary is the entry or exit of the water, which in some cases can vary. Respect the placement of the relief valve.
Regards

Responder
Diegomar
Diegomar
214
hace 5 años

Thank you very much Ricardo

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis