Hello how are you? would be to make some parts in a house and change the existing entrance pipes of Water (aysa) and Gas (natural gas) from the respective meters that are in front, through the garden and at least to the interior of the house ( I would join there with the current installation and then continue with the improvements later), one of the questions would be if you can take both pipes (gas and water) together to take advantage of the underground pipe (and / or wall), there should be some distance minimum? Is there any minimum depth? Anything else to consider? I would be having hot melts, thanks in advance!
Calemdq
Calemdq
23.097
hace 5 años
hace 5 años
Hello The rules to take into account are those of gas, which say that there should be a minimum separation of 20 cm with other services, water has no restrictions Cheers !
servimat1
servimat1
138.835
hace 5 años
hace 5 años
Hi. Place the water pipe under the gas pipe at a minimum of 20 to 30 cm. This is if the water perspires or drips the gas will not fall. This method is also used with electricity. Regards
servimat1
servimat1
138.835
hace 5 años

I did indeed make the mistake. Thanks for notifying. I edit

Responder
Ricardo Ab.
Ricardo Ab.
5.181
hace 5 años
hace 5 años
Hello According to MDQ Heating, but if you have the possibility of carrying it on the wall, it would be more convenient. At least the gas underground and in a garden has to meet certain requirements, depth, encased in bricks and protective mesh and warning about it. Regards
fabricio6687onda
hace 5 años
hace 5 años
fiate the regulation but a pipe of the other 30cm and should never cross, greetings
pablop2000
hace 5 años
hace 5 años
Excellent, thank you all for the contributions!
servimat1
servimat1
138.835
hace 5 años

Nice to help you. Regards

Responder
Ricardo Ab.
Ricardo Ab.
5.181
hace 5 años

Hello Three things for you to consider, in the case of gas. 1 ° As the double union connection is not allowed, it will be convenient to start from the house to the street. 2 ° If you are going to make the extension with thermofusion and the existing one is made of black or galvanized or epoxy spout, you must join with galvanic cupla (insulating cupla). 3rd If the regulation in the entrance niche has not changed, thermofusion pipes are not allowed, they must be an epoxy pipe. With which you will have to put another galvanic cupla. If anyone knows of any modification in the regulation on the latter please clarify.

Responder
Ricardo Ab.
Ricardo Ab.
5.181
hace 5 años

Greetings and thanks

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis