Sanitary

Connection of two water tanks at different levels from each other

joserra2000
hace 5 años
hace 5 años
I want to make this connection, could you tell me if it is feasible? Thank you.
Edurau
Edurau
835
hace 5 años

To the best of my knowledge and knowledge, you are driving in the opposite direction, that is, the upper tank should fill the lower one with a closing float, the filling will be popr the upper one, and the exit to the house will be through the lower one, with that you will never have problems, because the water must circulate systematically, and exchange continuously, without running the risk of having stagnant water in the lower one. luck

Responder
Ennio Montenegro.
hace 5 años
hace 5 años
Hi Joserra2000 To make it work and not overflow, you would have to put an electrovalve with a float switch or a WC tank fill type valve to the lower tank. By providing higher pressure to the upper tank, the lower tank will only be reserve and will deliver water when the upper one has been emptied. Comment doubts
joserra2000
hace 5 años

Thank you very much. Will it be necessary to put a jug on the bottom or just with the jug on the top will it be enough?

Responder
Ennio Montenegro.
hace 5 años

I don't know what you call jug. It will be float type switch for level control .. ???

Responder
joserra2000
hace 5 años

Sorry, in Mexico we call the tube to release the vacuum

Responder
Ennio Montenegro.
hace 5 años

If the tank is closed, you need to break vacuum when unloading, but you also need to dump the air when filling.
In short, it MUST NOT BE CLOSED.

Responder
joserra2000
hace 5 años

OK thank you very much.

Responder
joserra2000
hace 5 años

I made a mistake by pressing the button of the best solution. THE BEST IS THIS. Thanks again,

Responder
Walter dal farra
hace 5 años
hace 5 años
Hello Jose: Can you know why you want to do that? since I see it unnecessary. LUCK
joserra2000
hace 5 años

Hello, To put an extra tank at different levels of the main and take advantage of without modifying the filling that comes from the tank

Responder
danny_rosariorc
hace 5 años
hace 5 años
You must connect the upper tank to the lower one. From the bottom you will give water to the house, you will lose pressure by height. I do not understand why another tank, because there is a cistern. I would put a larger tank above or enlarge the tank. From your drawing how can it be. But you need a check valve for the bottom tank outlet. And floating entry in it too. The upper one has electric floating.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno