Blind well fills quickly.

cehar
cehar
28
hace 6 años
hace 6 años
Hello, I have a problem with the blind or black well, it happens that it fills quickly, it is a relatively new well (8 years) and it is not more than 2mtrs deep by 1.20 wide, I could not make it deeper because at 1.60 mtrs. a lot of water was already coming out (the sheets are very high in this area), today my patience filled me ... because yesterday morning I made it drain and today in the afternoon it is practically full, the well is only the discharge of the toilet. ... nothing more, neither soap nor pap, that's why I blame the napas
cehar
cehar
28
hace 6 años

Sorry .... I'm going to continue my question here because I published without wanting to, I don't know how to edit and it wasn't over ..... well, I have an old hole 2 and a half meters from the well ...... if I I put a pump? Is it possible that I can lower the level of the napa so that the well does not fill up so fast?

Responder
servimat1
servimat1
138.835
hace 6 años
hace 6 años
Hi. You can place a bilge pump without problems. The point is that you will do with that water. For cases of upper or upper layers, it is to place a tubed well. You arrive well below and the problem is over. Regards
cehar
cehar
28
hace 6 años

Sorry, what exactly is a well tubed?

Responder
servimat1
servimat1
138.835
hace 6 años

It is a well that is dug with a special machine at great depths and then a pipe is placed in the drilling. This allows you to reach great depths away from the napas. S use "common" sewer pipes of Ø 100 mm for jacketing. In this type of well, a deep napa is usually reached that has no contamination problems.

Responder
cehar
cehar
28
hace 6 años

I just want to lower the water level of the well, so I thought about putting a pump in that old hole that is 2.5 meters away. from the well (it was from an old hand pump), will it be possible to go down and not fill up so fast?
The water you take out will have an odor - obviously I don't intend to use it, but it's true, I'll have to see what to do with it.

Responder
servimat1
servimat1
138.835
hace 6 años

If they belong to the same middle napa as you would have to have the bomb walking all day. Depending on the age and capacity of the napa, it may be filled or restored often and constantly. I think the solution would be a well tubed as I told you or to make the well somewhere else, far from the napa. I leave a link for you to see how these wells are.
http://desagotesencordoba.com.ar/pozos/

Responder
cehar
cehar
28
hace 6 años

Give it .... thank you very much for your time!

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis