Ricardo, for the doubts to see if I understood well ... the tank collector would lower in my case (according to the plan of my house) ... 5 pipes of 1 "(32 mm in hot melt I think) of which 4 pipes of those would go to the entrance of each amb (cold water) and 1 pipe that would go to the thermos, would it be like that?
Hi Pablo, you understood well, it's a tip ... you can do it with 1 "or 3/4. With 1" you ensure a very good flow at all exits and forget about the shower problem. You spend a little more, it is true (it comes cheaper than a pressurizing pump) but at the time of bathing you will remember. You don't have to worry that the washing machine is working, that they use the bathroom or any kitchen faucet. The important thing is that they are independent descents, the pressure and the flow of each line will only depend on the tank. Regards