it doesn't reach my differential key

Jerson Ludeña Oyola
hace 5 años
hace 5 años
In my house I have a board in very good condition with perfect keys and in good operation but my differential key does not enter because there is no more space Is it necessary to buy another bigger board, or do I embed a smaller box next to the board where only my differential fits? which would be cheaper thanks for your replies
servimat1
servimat1
138.835
hace 5 años
hace 5 años
Hi. It would be cheaper and less problematic to place another small cabinet for the differential. What yes, it has the installation of correct way so that the cables are not tightened by the plate of the cover. It's very dangerous. regards
Pablitointegrado
hace 5 años
hace 5 años
If that were my board, I would choose to take out the 4 screws and remove the cover ..... then I would cut the cover plate so that a large square is left (That the square is determined between the numbers 1-3-5- 2) so that thermomagnetic and circuit breakers are visible to be able to operate them. Then, instead of the thermals being in that direction, I would put 2 DIN rails horizontally and buy new thermomagnetic to attach them to the DIN rails in conjunction with the differential circuit breaker ..... I calculate that they will enter you and they will be standardized (above powered and down de-energized). For that reason I would recommend you to inspect this type of thermals well since they seem old and it has happened to me that some have a only thermal replacement and not a magnetic one as the most modern ones have a spark arrester chamber and others. Regards!
elektomaq
elektomaq
62.202
hace 5 años
hace 5 años
Hi What is not understood is if the photo you uploaded is from your board or is a photo obtained on the web ... because on the one hand you ask between two options which is the most convenient and economical, and on the other hand you show a photo in where I already opted for an option so the question would not make sense, so I conclude that this photo does not show your board The cheapest option is going to be a box next to it. I would recommend a little bigger to give rise to some added future you remove the back cover from the big box you must break the wall a few centimeters between boxes to place 2 communication pipes. .Calculate the distance between boxes according to what they manage to cover their tapss so that it comes close to each other but does not overlap. Then, once interconnected, you swipe the box. You put the covers and these will cover the broken (as long as you have not broken too much) Cheers
elektomaq
elektomaq
62.202
hace 5 años

The stuffing box so that it has an edge and cover what you can break

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis