Ask about wall sockets with two legs and sockets.-

lilibel26
hace 5 años
hace 5 años
Hi, how are you? Thanks to all the people who can guide me from now on. -My problem is the following: I have the first option to buy a two-burner electric stove and as a second option an electric oven that comes with anafes up. -Now the issue is that in all I have two-leg sockets in the house, and I use them with three-to-two-leg adapters ... now if I use the microwave little, nothing happens, if I use it for 5 minutes, the adapter is very hot !! .- They told me I only had What to change the wall plug, put a three legs on the wall and ready ... now I am not very skilled in this and my question is: just fitting the plug is solved? and if I buy any of the appliances indicated will I have problems when cooking? .- Please if someone could guide me super grateful! .- I had a problem in my building and many months ago we have no gas ... Thank you and greetings !!!!!
lilibel26
hace 5 años

Thank you very much to all the members who answered my question !!!! .- I will call an electrician since I see that it is not as easy as I had been told.-Greetings to all and a thousand thanks friends !!!

Responder
elektomaq
elektomaq
62.202
hace 5 años
hace 5 años
Hi What you want to do is serious and requires a qualified or registered professional. All those outlets where you need to connect 3-leg cards, you have to change for the 3-pin sockets. Above all and very important, those of great consumption or engine appliances (washing machine fridges etc) adapter tabs are not suitable for this, are prohibited and dangerous. In fact if you can change all the shots and remove all adapters, much better The electric oven, two-burner stove or oven with stove are very heavy appliances and not only requires a separate circuit but will require the change of the sectional circuit (upright or circuit between meter and department) There have been cases even where departments have cut their gas and had to change the electric service from single-phase to three-phase to be able to have greater power than is the single-phase. you should also think about heating water and electrically heating so it is not just the kitchen Comment any questions. If you want more details I need to know your installation data such as sectional circuit measurements, consumption etc.
Ricardo Ab.
Ricardo Ab.
5.181
hace 5 años

I add to your answer very accurate by the way, that those devices (furnaces and microwaves) require grounding if or yes. Therefore, it is not only necessary to change the outlet, but to verify the grounding. Greetings.

Responder
ydd:alualo
ydd:alualo
2.847
hace 5 años
hace 5 años
Hello, to echo the request of lilibel26, I suggest a possible way out of the situation you are living. As I consider it is important to make daily food, and the costs can be very high with the use of anafres or microwaves, or electric oven, I suggest, a "Slow Cooker". Against what you can think of is a low-power and very useful appliance as well as comfort. Regarding the consumptions they go from 75w, up to 225w. which could represent the use of a pedestal fan until perhaps the use of a small refrigerator, which is commonly used in all homes. I invite everyone to analyze this use in homes and see the qualities as well as the possible incumbennts that I might have, I leave a link that I hope can be seen, since it was taken from the web, greetings to all. alualo. http://www.crockpotting.es/consumo-crock-pot/
Haru_No_Yuki
hace 5 años
hace 5 años
Hello, the ideal would be that you can connect directly without an adapter since the cable amperage is better used in this way as far as I understand, but in this particular case I could not say that it is solved. I explain that you cut the gas and you can buy an electric stove or an oven with burners up right? its consumption should be around 2000 W approximately minimum is an important fact that you should specify if possible, it would be necessary to verify that the section of the cable allows you that extra consumption, to avoid overheating the cable, both the thermal cable of that circuit as the general cable of all circuits and therefore see if the thermics are modified or a separate circuit is created for the oven. Changing the socket is easy, but if the cable is thin the same thing will happen to you, since the overheating is due to a larger consumption that allows the driver or a false contact.
Ojociego
hace 5 años
hace 5 años
A minimum contribution, note that in some cases, electric ovens are prepared for 20A sockets, that is, a little larger than the common ones. regards
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis