Household Electricity

Circuit breaker jumps when mechanical timer is turned on

Catu23
Catu23
12
hace 5 años
hace 5 años
Hello everyone! My problem is that when the timer clock of some luminaires is activated, the circuit breaker jumps even though this clock is not connected to it. I clarify that the neutral of the clock input is connected to the output of the circuit breaker (the phase is not connected to it). The problem may be because of the neutral? From already thank you very much!!!
elektomaq
elektomaq
62.202
hace 5 años
hace 5 años
Hello a circuit breaker or differential switch, acts by detecting a certain current difference between what enters and what leaves the differential If you connected a watch and took a pole of the differential and the other pole of another side, it is completely normal for this differential to operate since there the currents that enter and leave are not equal To avoid this, both the phase and the neutral (both) must be taken from the differential output or if the wish is not to pass through both poles must be taken upstream of the differential Regards
Catu23
Catu23
12
hace 5 años

Thank you!!!!

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis