New electrical installation in a house

Samanta83
hace 6 años
hace 6 años
Hello! I have to perform the new electrical installation in my house. He went on to describe. In my house I have: In the kitchen: Fridge, Microwave, small appliances (blender, toaster, multiprocessor, mini pimer, etc.), Gas stove, Ceiling light for led light, 10 power sockets, 4 light key. Laundry: Washing machine, Koihnor, dryer, LED light, 5 outlet and two light keys. In general: 4 LCD of 40 ", Home Theater Muteki, 3 PCs, 4 air conditioners 2 of 2500 and 2 of 3500; ceiling fans 3 M&M, LED lights, power socket 20, light key approx 10, Rowa smart lift pump and pressurizing pump of the same brand. The light service is from EDENOR, enter 220, I don't know much more. From the street (pillar) Start with thermal shneider 40amp. The cable is 6mm Sintenax. It is more or less a 30 meter run. When you enter the house, it is connected to a thermal shneider 60 amp. As it is an old and bad installation, we decided to change it. My question is: How and what products do I use for the new installation? The idea is also to place a tension protector. Make a board in the house where the thermal and circuit breaker of each room are or with a thermal, a voltage protector and a circuit breaker is more than enough? The air how would you install them? I know they have their own thermal, I should add the circuit breaker. With respect to the cables, does the category 5 agree or is it not necessary? Jablina is going to be placed at 2 meters. So we have cable to ground. I hope the description has served. Of course, thank you very much for helping me, Regards
elektomaq
elektomaq
62.202
hace 6 años

Your installation, as you describe it would not be right, we need more data to be able to recommend something appropriate,
Number of circuits
Number of shots
Number of lights
Supply voltage
Capacity of the air equipment
Housing surface

Responder
elektomaq
elektomaq
62.202
hace 6 años

Other heavy consumption loads such as anafes, oven, electric water heater etc

Responder
Samanta83
hace 6 años

Hello! Add in the question what you ask me. Thank you

Responder
elektomaq
elektomaq
62.202
hace 6 años
hace 6 años
Ok .... First we start inside, you need 2 power socket circuits, one special and one general with 2.50 mm2 and 16A thermal cables 1 light circuit with 1.50 mm2 cable and 10A thermal 4 air conditioning circuits (ideal) with 2.50 mm2 cable and 10A thermal c / u 2 circuit of pumps with cable 2.50 mm2 and thermal of 10A c / u the sectional line (general) to my liking should be 10 mm2 (sintenax) the general thermal 40A and differential also 40A the thermal 60 only serves as the head switch of the internal board
Samanta83
hace 6 años

Thank you very much for your help. Continue reading and I could perfectly understand what you said. Thanks for taking your time!

Responder
Samanta83
hace 6 años
hace 6 años
As I understood, could it be how you told me how it appears in the drawing? What does it mean: special and general current circuit? Thank you
elektomaq
elektomaq
62.202
hace 6 años

Why drawer the thermal of Aires and bombs, off the board?

Responder
Samanta83
hace 6 años

I have the pump ones in the laundry room. That's why I drew them out. And the air taking out the connections and placing its thermal where the air is.
Now I realize that everything should leave the board. And from there distribute, right?

Responder
elektomaq
elektomaq
62.202
hace 6 años

Yes, everything must come from the board. It makes no sense to place the thermal in a location close to the load (air conditioners, pumps etc)

Responder
Samanta83
hace 6 años

Oh perfect. Then: from the 40th thermal and 40th circuit breaker drift for all the rest.
The 60amp thermal where does it go? In the pillar of light?
And the last thing, what is the special and general circuit for electrical outlet? Thank you.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis