Forged corrugated pipe

MauroSL
hace 6 años
hace 6 años
I have been told that the use of the orange corrugated pipe is forbidden, is it? I was told that the AEA said it but I do not find any document that says it, if so .. why? Is PVC more preferred?
elektomaq
elektomaq
62.202
hace 6 años
hace 6 años
Hello Regulation AEA 90364.7.771 edition 2006 (effective) [color=#2980b9] 771.12.1: Unused conduits, wires and cables: (n) Plain or corrugated pipes of flame-propagating synthetic material or insulation, generally orange, in accordance with clause 7.3 of IEC 61386-1 (at the date of publication of this Section, IRAM Rule 62386 is in study). 771.12.3.1: General The conduits suitable for electrical installations in buildings were detailed in 771.12.2, and their assembly is allowed if the requirements indicated in the following subclauses are met. Pipeline systems not allowed, were described in 771.12.1. With regard to insulation pipe systems, in 771.12.1 n), it has been established that the use of flame-propagating pipes is not permitted. This restriction also applies to products which, irrespective of the color set by IEC 61386 (orange or orange) and of any other color, do not meet the required flame retardant characteristic. these are paragraphs extracted from the regulations where it clearly states that those pipes that do not meet the condition of being NO FLAME PROPAGANTS regardless of their color are NOT PERMITTED the orange pipe is attributed to it being a flame propagator, therefore it is not allowed other pipes for more than oranges may also fail to comply with this requirement and not be allowed so it is always recommended to read the rules of manufacture and technical characteristics of the product regards
agustinp
agustinp
2.247
hace 6 años
hace 6 años
I personally, when I use corrugated tubelectric use, I know it is under standard. There are corrugates that have no mark, a disaster. I almost always prefer blue hose
elektomaq
elektomaq
62.202
hace 6 años

I understand from comments from other colleagues that the blue hose does not meet the requirement of non-flame spread therefore would not be allowed.

Responder
agustinp
agustinp
2.247
hace 6 años

Curious ... now I look at the regulation, I had read that the semirigida pipe was allowed but I do not know if exactly this ... Then I fixed if at least meets the IRAM ... greetings

Responder
elektomaq
elektomaq
62.202
hace 6 años

I am referring specifically to the blue hose

Responder
elektomaq
elektomaq
62.202
hace 6 años

I am referring specifically to the blue hose

Responder
agustinp
agustinp
2.247
hace 6 años

but if not, which would be semi-coordinated? I interpreted it this way, but perhaps you are right. It seems strange to me because they have recommended it to me from very reliable sources and I have never heard anything like this ...

Responder
elektomaq
elektomaq
62.202
hace 6 años

I never used it. If you can do yourself the test do it. Submit a piece of that pipe to the fire to see what happens
I try to look for technical information of that pipe and I did not find anything so in the face of doubt I was guided by what they tell me
I try to find out if I find something about it and I'll tell you why on the street you're going to meet those who are fans of that pipe and who are against but there is no documentation that endorses one position or another
I find out and I tell you anything
regards

Responder
agustinp
agustinp
2.247
hace 6 años

It is true what he decided, I had it as more "famous" but looking on the internet does not appear almost anything
Now I do not have one, but I'll try. It really is not that it is fanatic but they are very comfortable to pass cables ...

Responder
elektomaq
elektomaq
62.202
hace 6 años

Ask several colleagues with whom I have contact and almost everyone agreed that a fire is on
No matter how comfortable you are to work, if you set a fire, you should not use
Anyway do the test when you have some piece at hand and I beg you to comment
regards

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis