⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta.🔥 Aprovechar oferta ahora 🔥
Dear, I have a GATTER 3000 sliding gate engine from PECCININ CP 3030N Rev. C board, suddenly it just closes, does not open, walks only to one side, before I stopped it midway and walked to both sides, from the remote . Now it closes, reaches the end and does not reverse the direction of rotation of the motor, when the remote is activated, it tries to start on the same side.
I await your comments.
From already thank you very much.
Greetings.
I don't know the truth about Peccinin engines, but it has happened MANY times with the Garen Combat board of the SEG brand.
According to what I understand is one of the relay, the best option in my opinion; Buy a new plate and replace it.
Greetings.
First check the position detectors or micro suicides or magnetic detectors, if 1 of the detectors is damaged it opens and does not close or close and does not open and if it is halfway it goes in the same direction. It could also be one of the relay investors that got stuck and does not allow investment
if it is one of the detectors, change it if it is one of the relays' and it does not have an electronic card, change the relay and if it has a card then take it for repair or replace it with a new one.
I hope this solution serves you, remember to comment what you did to solve
My mistake about asking to close with accepting my solution, can someone reverse the negative point? I didn't know that it couldn't be done when I answered this question and that was a long time ago, thank you