samuli
samuli
4
hace 5 años
hace 5 años
Good, I have a garage door with the VIVO-M101 (M) control unit of Erreka, the case is that I have connected a fluorescent that turns on for a certain time, when I open the door. But there are times that I stay in the garage longer and of course, the light goes out and to turn it on, I have to operate the door again. Do you know if there is any way to do something so that with a button the light is activated again? greetings and thanks
servimat1
servimat1
138.835
hace 5 años
hace 5 años
Hi. it would be necessary to see the connections of the plate (of the light) and place a common switch. The fluorescent will remain on as long as you do it from the switch, without limits. Can you upload a photo of the gate plate connections? regards
samuli
samuli
4
hace 5 años

These are the photos: https://ibb.co/qrvpX7c
https://ibb.co/44L8CFH
If we see the cables from the right, they are the ones that are after the two free holes in the first image, in the second they are the connected ones where it says courtesy light.

Responder
servimat1
servimat1
138.835
hace 5 años

An external switch should be placed on these same contacts. When it is on or with its contacts closed the light will turn on until you turn it off. What if, be careful to turn it off from this switch since otherwise it will never turn off for more function than the gate. regards

Responder
Control Market
hace 5 años
hace 5 años
More than a switch, a selector with NC and NO contacts must be used, so that when the selector is OFF the light can only be turned on when the motor is activated, and when the selector is ON the light turns on directly, but at the same time the energy coming from the control unit is going to be cut, the ON position is indicated in the diagram, if you look at the two contacts that go to terminals G7 and G8, the position OFF, G8 joins that L, while G7 with the one that goes to lamp.
Control Market
hace 5 años

I wanted to write "... but at the same time cut the energy coming from the plant, in the diagram ..."

Responder
samuli
samuli
4
hace 5 años

Perfect, I will try to see if it goes well, thank you very much!

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis