Cecilia: for a combustion box, regardless of whether it is a grill, bread oven, or, heating, to work well with respect to the suction of combustion gases, it requires that the section of the inlet mouth and that of the duct of the chimney, have a ratio of 1 to 0.3, that is, chimney conduit 1/3 of the mouth of the combustion box, in addition to a height of no more than 0.40m from the base of the chimney, must have a maze that makes that the descending column of the winds, they are redrawn upwards, they call it, lung, and, if at the exit to the four winds, there is a wall that acts as a screen that stops the winds, it will be necessary to put on a cap to help To suck the fumes. luck