Whirlpool washer makes the differential jump ...

daniriq
daniriq
787
hace 5 años
hace 5 años
Hello to the forum ... the failure of the washing machine is not always, but on several occasions it makes the circuit breaker trip as soon as a program is selected ... I did the following tests disconnecting all the peripherals, such as motor, resistance, pump, deworming filter, cable earth, less platelet programs ... and the problem persists. Well ... I have discovered that in the outlet there is no third cable, the discharge to ground ... but if there is a cable with javelin on the board of the house. On several occasions I have had similar failures in other washing machines in the workshop, but I have solved them by removing the parasiticide filter or replacing it. My questions are: is it possible that there is a leak to the housing of the washing machine (rare because I have disconnected the ground wire), that the platelet fails ?, that the circuit breaker fails or is it very sensitive ?. Now if it works well when plugged into an outlet connected only with the thermomagnetic key ... someone with any opinion would appreciate ...
lusangor
lusangor
56.366
hace 5 años
hace 5 años
Hello, check with a multimeter, if there is a leak to the housing, if there is none, it cannot be the washing machine. Regards
Walter Molina
hace 5 años
hace 5 años
Hello, it is very likely that the problem is in the outlet, it does not matter if you do not have the ground wire because the circuit breaker still detects leaks.
mati nuñez
hace 5 años
hace 5 años
Something very similar happened to me. In the eagerness to solve the problem, the third time I tried everything connected again and not accusing any problem ... I load it with clothes and start walking, as soon as it started ... I burned the plate. Luckily the machine was mine and not from a customer!: |
daniriq
daniriq
787
hace 5 años
hace 5 años
Hello, I have reached the conclusion that it is a platelet failure, now in addition to making the circuit breaker the pump is running, when some program ends, thanks to the help forum ..
mati nuñez
hace 5 años

And it looked like this? You didn't fix it? What you have to do is connect one by one and test the peripherals. Comment the solution

Responder
daniriq
daniriq
787
hace 5 años

Sorry for the delay, the problem is on the board ... it was changed and it worked perfect!

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis