Good afternoon lusangor friend, perform the tests that I indicated and the result was the following the pump works perfectly mounted, feed it directly and ejects the water, also directly feed the motor drive and it also works, I can lock the door and the door lock level sensor and the fault continues, now fills and washes, does not centrifuge to squeeze, the step to rinse and performs it perfectly, but does not spin, check all the cables and nothing is left for me to just check the motion sensor and the electronic card, for true does not give any code, regards
Sorry I forgot to comment that, it does not drain in either process, wash and rinse, greetings
Actually, none of the components did that test, in the week I do it and I comment, thank you and sorry for the inconvenience
Good afternoon lusangor, perform the test you indicated, place the multimeter on the power cables and no voltage reaches only 1.8 - 2.5 mark, intermittent, I thought to also perform it to the motor drive but they are the same cables, that is, the pump and the drive are connected in parallel according to the diagram and check it by checking the wiring. Another thing, I tried the trainer is fine.
As I mentioned before check the connections are fine and the cables should also definitely be the card, I thank you for all the help provided and instructive, greetings