⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Philco

Philco PH 708 does not stop the WEAR. E1 (does not complete the Charge

Fran Beláustegui
hace 6 años
hace 6 años
Strip error E1 (related to the water inlet) Not only that ... the washing machine enters the cold water (already probe changing the filter and also at different times when there is better pressure in the neighborhood, is that I do not have a water tank) but almost never finishes loading or never leaves of draining the water pump. then the timer practically remains anchored since it never gets even the minimum water load. There has to be a problem with the drainage that does not allow any function to be terminated or rinsed or washed or soaked. In summary; It loses water at the same time as the load. The washing machine is second-hand and has a drum of another washing machine (it is a Frankenstain) and it is still under warranty the Technical Service takes over. But I live far away so I have to be clear about what to claim, ask or perform. Regards. Att, Francisco Belulategui
dataelectronica
hace 6 años
hace 6 años
Hello, the first thing to control is whether the water goes by pump action or by suction effect. for the first one he will listen for the second check the height of the hose and if you have any hose addition that is not from the washing machine remove it and try
Fran Beláustegui
hace 6 años

Hi Yes. The bomb is heard. and it goes by action of the same. The problem is that this is constant so it cannot load.
For the second. the only hose it has is that of the washing machine that is a short corrugated (less than 2m)

Responder
dataelectronica
hace 6 años

Well, if it is a pump action, first see if the pressure switch contacts are not locked. Blow to listen if activated. If the problem is good, the electronic board is

Responder
luis38
luis38
95.432
hace 6 años
hace 6 años
Dear, it is possible that the plate is damaged, so it permanently energizes the discharge pump. Disconnect it and check what happens. Regards
electrototal2015
hace 6 años
hace 6 años
Hello I am with the same problem, with a James LSE-1012 washing machine, CONNECTIONS AND CHARGING AND UNLOADING AT ONCE I disconnect the discharge pump and load and wash normal but when connecting the pump permanent discharge, remove the plate at a glance no broken element is seen and no burn is seen on the plate. I do not know what to do.
alturasbal
alturasbal
27.174
hace 6 años

Hello, open a new question to receive the corresponding help since this belongs to another person, if we answer here we will create confusion to the main topic, greetings.

Responder
electrototal2015
hace 6 años

Aaaaa ok I apologize for the case.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis