Hello, error E2 is associated with problems with the magnetic switch of the lid, check the front of the lid below, there must be a small segment that has a magnet inside, close some metal to check that the magnet is still there, sometimes that magnet falls and therefore stops activating said switch, if it still has the magnet you will have to take out the logic card and check the state of said switch that when you close a magnet it closes, if it does not have the magnet you can place it a piece of bad PC hard disk magnet that are excellent for that, do the tests and comment to continue helping you