Hello gallorojo from what I saw the winding is fine, the three coils measure me well, what I notice is that the sensor does not measure anything at any of its terminals.
Red cock half the Hall sensor well and I have resistance place the multimeter in continuity and from left to right black tip in 1y5 measures 1840 omns 1y4 1040, 2y5 1840, 2y4 1050 and 4y5 1186 I suppose the sensor is ok? Because it marks the error Pf that what I was seeing may be block, pump or solenoid valve, not just the current. I will arm it again and try
"PF" error: protection against power cuts or temporary interruptions. When restoring power and such message appears, press and hold any key until it disappears "
Hello, assemble everything again to see if it threw me an error and it really made me an error LE that is the sensor I will buy a new one and I will see how the solution remains like this
Hello Luis, the error persists LE and I already changed it for a new one, the washing machine works and after a wash or two it returns with the same error, what could it be like that, can I check?
Hi Luis of the axis does not lose anything is impeccable and from the plate to the sensor how much would be the value to see if the voltage reaches the sensor.
Hello Luis, it may be that the magnets have already completed their cycle, so the lady told me she is 10 years old, the washing machine