washing machine gafa genesis 6800 throws failure after each restart.

fer sando
hace 5 años
hace 5 años
Washing machine throws failure after each wash restart. According to the failures of the manual (7 flashes, over-level failure), a level sensor was checked and, at a glance, its operation is adequate. pump status and operation was checked (ok). the failures are the following: the washing is restarted, it starts with a previous drain and then when the drum is dragged it goes into failure and the drain starts again and the 7 flashes of the 3 leds begin. Spinning function is carried out starting the previous drainage, then rotates the drum and stops as soon as possible leaving a long time without throwing any fault. Of course I appreciate the knowledge and contributions to repair the washing machine. a pressure switch, chamber and sleeve check was carried out and nothing is noticed that attracts attention. Washings and tests were performed without chemicals, only water.
luis38
luis38
95.432
hace 5 años
hace 5 años
Dear, check that the hose and air chamber of the pressure switch is not obstructed. Also verify that there is no excess soap generating a lot of foam. Regards
fer sando
hace 5 años

a pressure switch, chamber and sleeve check was carried out and nothing is noticed that attracts attention. Washings and tests were performed without chemicals, only water.

Responder
luis38
luis38
95.432
hace 5 años

Dear, if you have tension in the pump before starting it, it is a sign of a defective plate and this error occurs. Regards

Responder
fer sando
hace 5 años

Hi Luis! First of all, thank you very much. Perform the following test to verify if there is tension in the drain pump: place a tester on the drain pump terminals, wash restarted, it starts with the previous drain (220v during the process), then the water charge continues (0volts during this process in the drain pump), cut by level and start to rotate the drum, just there you can see the voltage reading in the drain pump, and then it goes into failure (7 blinks).

Responder
luis38
luis38
95.432
hace 5 años

Dear, during washing you should not have tension in the pump. If when starting to wash, there is tension in the pump and the error code is produced, check if the plate shows traces of moisture or insects.
If the plate has no traces, the micro of the plate may be damaged and should be replaced. Regards

Responder
fer sando
hace 5 años

Hi Luis, first of all I appreciate your contributions and knowledge, they led me to a successful repair. I replaced the plate and the washing machine regained its normal operation. Thank you in advance, thank you for teaching me!

Responder
Romer Romer Romer
hace 5 años
hace 5 años
how much did you pay for the plaque because the same thing happens to me! Thank you
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis