Hello, thank you very much for the help, check the water inlet and it's fine, clean the filter, relive the hose, there is good water pressure but ... The same ... I have no choice but to remove the electro valve not to can check it? Thank you
Friend, just for proof, swap the electrovalve tabs and try again. Comment the results. It is to corroborate or rule out problems with them. Regards
if I did it and blowing the entrance they act well both of them I think they work well ... I put it together a wash worked perfectly and then in another I already shot the same error of the LEDs flashing together 2 times ...
Hello, it can be wiring problems or connectors of the plate to the solenoid valves, or they can be sulphated or loose in the inserts. Regards
Hi look, I think I'm going to check the electrovalve why there is nothing unusual in the filter or hose .....
Also check the pressure switch, blow through the piquito until it clicks, then hold the air and check if it clicks again, then it is because the membrane is punctured, he says, greetings.
Well the problem was that it was all dirty with soap and fluff in the rubber that rises from the drum to the loan hose. Thank you very much to all the comments and help received !!!! Problem solved!