Javier Nicolás guzman
hace 5 años
hace 5 años
Good evening friends of the forum !!! Friends I dedicate myself to the repair of washing machines and refrigeration in general ... well now I am having a problem in a washing machine aab 6.5 the client called me because the washing machine stayed if I even turned on a single light of the plate and much less function remove the lid and well the plate was with the inflated condensers and the silicone all stained in an area ... test the pump directly and electrovalvula also everything seemed fine .. I bought a new plate and put it to work, it worked well until the time of drainage and the problem is that the pump is energized for 15 minutes approx. and I get the error cold water and hot water intermittently. Try the bibina that activates the centrifuge directly and is doing very well ... the door suitch also has continuity ... this problem is living me crazy if someone could help me I would greatly appreciate your best regards !!!
alturasbal
alturasbal
27.174
hace 5 años
hace 5 años
Hello, the error refers to problems with the emptying, when it reaches the emptying stage, it controls whether the pump is flowing, if it arrives and does not empty, lower the hose to the floor and check that the water flows smoothly, if not There may be an obstruction in the system, check this and comment, regards.
Javier Nicolás guzman
hace 5 años

Thanks for helping me friend! The pump works perfectly and drains everything .. the problem is that after sqcqr all the water in the tank is energized it and no more until it gives error .. cold and hot water intermittently ... I also discovered that the pressure switch Electronic direct current arrives and not 5 volts direct current as it should and keep in mind that the board is new .. thank you very much for your time! !

Responder
alturasbal
alturasbal
27.174
hace 5 años

When it starts to empty, take out the pressure switch hose to see what it does, if the pressure switch is electronic, it would have to reach 5 V DC, did you get a plate equal to the previous one? Regards.

Responder
luis38
luis38
95.432
hace 5 años
hace 5 años
Dear, keep in mind that normally when there are "inflated" capacitors, it is indicative of voltage spikes. Consider this for the next board. Regards
sebastio
hace 5 años
hace 5 años
Hello I changed the power plate and now the washing machine does not start makes a "tac tac tac" and the display and some LEDs flash all the time in that state, I do not know how to face it.
alturasbal
alturasbal
27.174
hace 5 años

Hello, to be able to receive the correct help you have to open a new question and express your problem, this contribution already has a month and is valued as a solution so nobody will look at it and your query will remain unsolved, greetings.

Responder
sebastio
hace 5 años

If I opened a new post about it, thank you very much.
Regards.
Ing, Sebas

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis