7500

Centrifuged

miguel negro
hace 6 años
hace 6 años
Hello to the forum, I have a 7500 aquarium glasses and it does not centrifuge well, the client tells me that, he accommodates the clothes, he tries to spin sometimes he does it and sometimes he does not. Today I went to the home to try it and I could see that the thermo-actuator works by releasing the brake, the capacitor was going to change but the mf was not very readable, it would seem that it would take 10 micro farads, I would like you to confirm that capacitance? Now if the capacitor changed but the fault persists, what other fault could it be? From already thank you very much.
luis38
luis38
95.432
hace 6 años
hace 6 años
Dear, it may be that the imbalance sensor is being activated. Check whether it centrifuges normally when it is unloaded or not. Regards
miguel negro
hace 6 años

Hi Luis 38, without centrifugal clothes, but the client says that he notices less RPM, with and without clothes, with respect to the imbalance sensor where is it? Accommodating the clothes should work,

Responder
luis38
luis38
95.432
hace 6 años

Dear, the sensor is the pendulum that is in the left rear corner, under the cover of the solenoid valves. Also check the belt tension. Regards

Responder
juan guillermo caceres
hace 6 años
hace 6 años
Companion, the capacitor is 10mf check with a metric meter if it is within those values. Regards
Claudio Persson
hace 6 años
hace 6 años
Hi miguel. In effect, the Gafa capacitor is 10uf. Initially, I proceeded to check that the cover switch does not have sulfated contacts. If so, remove the sulfate with vinegar and pass a fine sandpaper. If the contacts are good, what you could do is bypass the lid switch, schedule a spin and manually check if, once the traction motor is operated, the basket rotates freely together with the agitator. In this way you would be ruling out a mechanical problem (transmission box). If changing the capacitor does not solve the problem, I proceeded to check the state of the motor (the impedance of the coils should derive from approx. 28 ohms). Greetings to you and colleagues ..
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis