Dear Luis 38, to continue learning with you, I tell you that the connection with the diagram of the plan and the washing machine did not work, now when you tell me to change the pressure switch cables, I learned how you indicated and the washing machine started working perfect, now my question is why did I have to change the cables? maybe it's a plane error, or the plane resembles this washing machine or the pressure switch is not original,
What is cable 13?
What is cable 16?
What is cable 11?
What is cable 12?
It is more to make it clear to me as to the rest of the Forista
Dear, what happens is that the classical nomenclature of the pressure switches is used in the circuit, (11, 12, 13). Currently the manufacturers decided to modify the numbering for some reason.
The 11, is the voltage input. On 12, energize the solenoid valve. The 13, energizes the timer and the rest of the machine. The 16 is the anti-overflow level. Regards
ok, thank you very much after the change you recommended me, the team started working normally