Hello I need if you can help me please with this situation I have an awh654 luxury link with a 4-contact pressure switch (12-14-11-16) and 4 wires that go to it. brown black hood, brown black hood, brown and a double brown. The problem is which goes where I can not interpret the electrical circuit that rose Luis 38. Well I have different numbers of contacts. I would appreciate your help . Thank you
luis38
luis38
95.432
hace 6 años
hace 6 años
Dear, here I send the circuit again: The difference is that the pressure switch has a number 13, which would be 14 of yours and 14 of the circuit is 16 of your pressure switch. Regards
gabito 43
hace 6 años

Hi, thanks for answering, I understand your answer, the wires are not numbered or identified and I can't interpret the circuit. What if it's okay? the 11 goes to the blocapuerta, the 12 would go to the valve, and the 13 and 16 where? From already thank you very much . I will value your help

Responder
luis38
luis38
95.432
hace 6 años

Dear, 13/14 goes to position 3 of the programmer and 14/16 is common to the solenoid valve and pump and to the terminal 3T of the programmer. Regards

Responder
gabito 43
hace 6 años

Hi Luis 38 Thank you very much I'll see if it goes ahead and I'll let you know. From already thank you very much . regards

Responder
gabito 43
hace 6 años

hello luis38 walked everything very well, the only thing that the water level is very low, the pressure switch is oval whites, do you know which screw you have to touch to raise the level a little? the lung already checked and it was fine

Responder
luis38
luis38
95.432
hace 6 años

Dear, if the water level is lower than one you have as a reference, replace the pressure switch. Remember that a larger volume of water does not imply a better wash result. If the water reaches the edge of the bellows, the level is fine. Regards

Responder
gabito 43
hace 6 años

hi luis38 thank you very much for your help. regards

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis