Good evening, I'm finishing repairing a Luxury Link EwD07A.

Damian Paz
hace 5 años
hace 5 años
The problem I have with this washing machine is that at the time of centrifugation the actuator does not operate and then the drum does not rotate and the pump does not drain. The pump is fine. I tested it alone. But the voltage that reaches the pump when I program it for centrifugation is only 140v. And only the vane is rotating. Could it be that since the actuator does not work, the voltage corresponding to the pump does not reach? From already thank you very much . Damian
luis38
luis38
95.432
hace 5 años
hace 5 años
Dear, the actuator and the pump work in parallel. If they reach 140VAC at the pump, the same voltage must reach the actuator. Remember that both devices work with 220VAC. If only 140VAC arrives, the board may be damaged. Regards
Damian Paz
hace 5 años

Good morning. Well Luis38 I will test the voltage that reached the actuator. Just as the actuator is not in good condition I have to change it. Then I tell you how everything goes. Thanks.

Responder
Damian Paz
hace 5 años

Well I tell you that now I am testing the washing machine the voltage that reaches the Actuator is 140 / 150VAC. The same one that reaches the pump. The actuator I have to change it, I tested it live alone and it is damaged.
Would it be plaque problem directly? Thank you for your contributions.

Responder
luis38
luis38
95.432
hace 5 años

Dear, both pump and actuator must have you 220VAC. Regards

Responder
Damian Paz
hace 5 años

Thank you very much Luis.If the plaque is the problem, thank you for collaborating and giving me a hand.

Responder
Richard1818
hace 5 años
hace 5 años
The same thing happened to me and I solved it by changing the plate.
Damian Paz
hace 5 años

Great, thank you very much Richard.

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis