hace 5 años
hello good day friends, I tell you what happened my client calls me because his new washing machine does not start the program so I recommended that he claim the guarantee of the same, goes to the guarantee and supposedly they solve it. When moving the washing machine in his van to his home, he pockets the top cover and detaches himself from the washing machine when he arrives at the destination he just notices. Then he calls me again so that I can solve the question is that I turn on the washing machine and turn on all the lights on the platelet, then I begin to start the washing function flashing. bypass the door mic (block door), measure the voltage in the solenoid valve and the 220v does not reach it, and the fault remains the same, that is, it is pressed in the washing function. I would like to know if it has any sensor other than the door micro and if it can be canceled or bypassed, it already controls continuity in the solenoid valves and in the drain pump and they are perfect. I'm going to thank you for your help, greetings igor!
igor
igor
15
hace 5 años
hace 5 años
Hi Juan Guillermo After so much dancing I found the solution has a magnetic sensor that lacked the magnet so what I did was look for a magnet that I had in my workshop, it was bigger and I got it with tape and I close the circuit and I start I hope you serve. greetings igor
juan guillermo caceres
hace 5 años

Well Friend, I'm glad you solved it, I was unaware that this washing machine carries that kind of sensor, thanks for sharing the problem. Regards

Responder
juan guillermo caceres
hace 5 años
hace 5 años
Hello, check the pressure switch terminals if they are properly placed, in the subject of cover with bypassing the microphone, it would be canceled, the other would be but it can be very remote that the ignition microswitch is not sending the order. Regards
igor
igor
15
hace 5 años

Hello Juan Guillermo, I'm going to review what you told me, then I thank you very much

Responder
igor
igor
15
hace 5 años

Hello Juan Guillermo, check the pressure switch and I thought it was wrong, then replace it with a new one and it remains the same, the strange thing is that it does not throw me any error.

Responder
juan guillermo caceres
hace 5 años

Hello, check connectors and wiring of both the pressure switch and the solenoid valve, it may be that the board sends the signal but does not reach the peripheral and therefore does not acknowledge error, interpreting that it is working but it is not. Regards

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis