Thanks Alturasbal ... I think it's like that ... but the only drawback is that I have no reference to what triac to replace ... the ones I have are not identified ... I have two types ... TIC226D .. and 97 A8 ... which one do you think is going ???
In addition to the triacs ... supposes that the microprocessor could have been damaged .... how do I prove it ??? Thank you!!!
Hello people!!! I already changed the triac and their associated resistances ... some were open ... when I tried them I commented ... arms!
Well ... try the repaired board and it works ok. The only thing I observe is that it cuts the water to the limit of filling the drum ... will it be normal like this ???
Thank you...!! Sorry for the delay in answering ... I took a few days off ... best regards !!!