UNICOMMAND 116

Triacs of Drean 116 washing machine?

yojoselo
yojoselo
264
hace 5 años
hace 5 años
Hi. I would like to know which of the two triacs is that of the centrifuge? Thank you.
gallorojocapacitor
hace 5 años
hace 5 años
The triac that is activated in the centrifuge is the one on the right (seeing your photo), that is, the drum is turned clockwise, the other is counterclockwise, if the machine washes correctly but does not spin, it is not a problem for the triacs
yojoselo
yojoselo
264
hace 5 años

Okay. I wanted to know that. Since the washing machine turns me on when (washing) on one side and does not spin. Therefore, the triac that I am looking for is the one that causes this (absent) spin + the spin.

Responder
yojoselo
yojoselo
264
hace 5 años

Oh, and the machine goes (lava for both sides) because I tried it with another plate.
Thanks also Rollingstone20.

Responder
Ppstone
Ppstone
87
hace 5 años

You're welcome. A greeting.

Responder
Ppstone
Ppstone
87
hace 5 años
hace 5 años
Hello friend, it is very true that if there was a colleague who had already repaired this washing machine I had the circuit at hand I could tell you with certainty which of the two triacs is the one that controls the spin motor. For the rest of us, seeing the image of the circuit and being able to say what the spin triac is is almost impossible. I can help you in this way: look at the card on the other side, the side of the tracks and welds, and follow each of the lines that reach the pins or legs of each triac (in reality they are only 6 lines). The image I uploaded is that of a basic connection of a Triac along with a load (drying motor) and the starter circuit. with some variants this is the circuit used to connect the triac to any load, if you rely on this diagram you will realize that a triac is necessarily connected to the load to which it has to control, and on the other hand to a pole of the electric current. I think this will help you to find out which is the triac that controls the drying motor, if you have any questions, tell us.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis