Hello friends !! I have a washing machine drean 8.12 to which the customer changed the drain pump because it did not work according to him. But after that, the washing machine continued without draining or washing. He called me, I went and I changed the pressure switch that didn't work, so the washing machine started to wash, but it doesn't drain and therefore doesn't spin. I already tested the pump, the solenoid valves, the pressure switch is new, the door block works, the cables from the platelet to the pump have continuity, but it is "hung" there and does not throw me any errors. They could be the carbons of the engine, but as I said it works to wash, and must first drain. I would really appreciate if you can guide me
alturasbal
alturasbal
27.174
hace 5 años
hace 5 años
Hello, if at the time of draining there is no voltage to the pump, it is because the board is broken, you have already checked the wiring, pressure switch and so on, you just have to suspect the board, greetings.
alturasbal
alturasbal
27.174
hace 5 años

If the previous bomb was burned it was the culprit to break the traic that controls it, greetings.

Responder
horaciok119
hace 5 años

Thank you very much alturasbal, it is exactly what I said to the client, I also forgot to say that I tested at the time of the failure, and the pump did not reach 220 volts, the reading was zero.
I thank you very much for your answer, because although I suspected that problem, I wanted to make sure since the plate looks good (I had already taken it out to see the triac) thanks !!

Responder
ROBERTO BERENYI
hace 5 años
hace 5 años
A Blue does not wash, nor does it start if the pump is not connected, or is burned, or its triac is damaged. I would give error 7 input. If it stops, but does not give an error, it is caused by a partially short motor.
horaciok119
hace 5 años

Thank you very much for the data Roberto, I will verify that the engine is fine, but wash well both ways, only that it does not drain and therefore does not spin

Responder
Vlack22
Vlack22
140
hace 5 años
hace 5 años
The most likely thing is that it is a platelet error if you can identify the triac that controls the drain pump would be great and if you know how to change it much better .. Luck
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis