Thanks friend Juan I know that it is auto balance.but I did not know that the noise was normal THE PROBLEM IS THAT I LEVEL IT WELL. BUT ALWAYS THE FAILURE PERSISTS WHEN I TAKE IT TO CENTRIFUGAR I TURN THE TACHO BUT ONLY DOES IT SLOWLY AND CONTINUES TO TICK AB AND SO FOR 20 MINUTES AND DOES NOT GIVE THE REVOLUTION I STRONG TURN DOES NOT ADVANCE
Hello, well as I express, the plate is detecting a rolling error and therefore does not enable, try doing it without garments and comment the result. regards
Friend thank you for answering the test I am doing to the empty bone with nothing something I notice is that when removing the belt the engine if it turns strong and does the whole process
Well, the test should be done with the strap on to check if the spin is started after the AB. regards
Hi friends, probe with straps placed with and without clothes and does not work still doing auto balance and does not advance the program CAN BE ABOLISHED THE AUTO BALANCE
The odd thing is to rotate without a belt according to you speed of centrifugation, check the coals and clean the armature. AB can not be overridden. regards
thank you friend and disarm the whole engine and everything is in order brush or coals, tachometer, fields, everything well the only thing that makes me doubt that the belt is very tense and I do not know what to think because if you remove the belt does the process well
Although the belt is silicon which allows some stretching, being very tense does not help at all because the opposite is achieved, with forced bearings and overheating of the motor coils. regards