Excellent 8.12 Blue G

Excellent Blue 8.12 p when rinsing does not stop loading water

Jasxxx
Jasxxx
3
hace 5 años
hace 5 años
Hello people, it is an Excellent Blue 8.12 p I put it in point 1 and everything works normally until you reach the rinse load the water begins to work but does not cut the water inlet, continues to load, I have cut the power and stop, I thought to change the electrovalvula they say? Thank you
juan guillermo caceres
hace 5 años
hace 5 años
Hello, it may be problems of the solenoid valve, that your waterproof system is defective or it would be a matter of electronic board that the triac that governs this solenoid valve is troubled. Regards
Jasxxx
Jasxxx
3
hace 5 años

Thank you for the answer, and excuse my ignorance referred to in a tight system? Thank you

Responder
juan guillermo caceres
hace 5 años

I refer to the hermetic system of the solenoid valve, sometimes the tartar and sediments carried by the water network damage the internal menbrana that can no longer fulfill its function and is "open" indefinitely. Regards

Responder
Jasxxx
Jasxxx
3
hace 5 años

Thank you, are the solenoid valves generic? because I have another washing machine and I wanted to try changing it to see what happens

Responder
juan guillermo caceres
hace 5 años

If the tab insert is the same, you can perfectly exchange them and prove what results you get. Regards

Responder
favallpa
favallpa
2.523
hace 5 años
hace 5 años
If you only do it in the rinse, I think it's a programming problem. since if in the other programs it works well, there is no problem either in solenoid valves or in triac.
Jasxxx
Jasxxx
3
hace 5 años

Thanks for the answer, when it reaches the point of rinsing load the water starts to work but does not cut the water inlet, I have touched the solenoid valves and only one feels hot, I don't know if that is normal?
If it is a programming problem, what steps should I follow? Thank you

Responder
luis38
luis38
95.432
hace 5 años
hace 5 años
Dear, to confirm the origin of the problem, check if the solenoid valve that is allowing the passage of water is energized or not, (220VAC). If you have tension, you might suspect plaque. If it has no tension and allows the passage of water, the valve is defective. The strange thing is that it does not give the overload error when exceeding the water level. It would be interesting to know what happens if you let him follow the cycle. It could be that since it is a complete washing cycle, this is part of it, as is the case with other brands that start working, but continue to load water for a few moments. Regards
favallpa
favallpa
2.523
hace 5 años

I may not understand the question of JASXXXX but if the whole program works normally and only fails in the rinse, I don't think it's a solenoid valve problem .......?

Responder
Jasxxx
Jasxxx
3
hace 5 años

Hi Luis, thanks for answering, change the solenoid valve, put the program on 14 (rinse) and continued loading even after starting work, it did it at a level exceeding about 5 cm the lower level of the door (no load, no clothes ) Cycle normally.
Now I'm going to try it with load
One thing I noticed in the solenoid valve that I pulled out, is that a mouthpiece (the one in the rinse, I think) had a color pulling light ocher.
I hope everything goes well, thank you all for the help, thanks

Responder
luis38
luis38
95.432
hace 5 años

Dear, it can be a normal part of the program. If it were abnormal, the washing machine would stop the cycle and give you an error message. Regarding the color of the solenoid valve is normal. The current ones differ in color to the oldest ones. Regards

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis