I refer to the hermetic system of the solenoid valve, sometimes the tartar and sediments carried by the water network damage the internal menbrana that can no longer fulfill its function and is "open" indefinitely. Regards
If the tab insert is the same, you can perfectly exchange them and prove what results you get. Regards
Hi Luis, thanks for answering, change the solenoid valve, put the program on 14 (rinse) and continued loading even after starting work, it did it at a level exceeding about 5 cm the lower level of the door (no load, no clothes ) Cycle normally.
Now I'm going to try it with load
One thing I noticed in the solenoid valve that I pulled out, is that a mouthpiece (the one in the rinse, I think) had a color pulling light ocher.
I hope everything goes well, thank you all for the help, thanks