Good. Consultation for the problem of the PPA brand sliding gate motor. It works on the side for approximately 2 seconds and cuts (it is noted that it is the plate since the relays are heard), towards the other side it does the same if I turn on the remote shell again.
I assumed it was slow or working but is already reviewed. I see that it has a cable that goes to a lap counter or tachometer, so I distrust it (I don't know if it can be tested) or possibly the board has been deconfigured or erased since the installation did not find any limit switch sensor
It is the first time that I enter this type of equipment but I work in electricity, alarms, air conditioning installations and I have general knowledge in electronics, only I don't even know the model of the board to find accurate information.
Upload photos to anyone with informacio that can provide IMG_20190524_185418070.jpg [252.39kb] IMG_20190524_185330219.jpg [206.67kb] IMG_20190524_185433232.jpg [468.77kb] IMG_20190518_135426770.jpg [206.78kb]
The photo of the control card is not clear. You should look for the model, it is very close to the condenser and above the text Ind. Brasileira. It is of the type P22XXX V Y.YY
Then check if the FC jumper is closed. If so, it is with the end of a digital career, without magnets. At the gate, check if it has physical stops so that the gate stops at the closing and opening.
Probably that type of card is programmed with a remote control so make sure you have one with good batteries.
Once you determine the model (P22XXX) you look for it on the internet and now ... simple.