⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Excellent 8.12 Blue G

cable cut

ELOKODELASKOLINAS
hace 6 años
hace 6 años
I HAVE A CELESTE CUT WIRE IN THE LAVARROPAS, IT IS CUT IN THE LONGEST PATH THAT COMES FROM THE WATER LEVEL SENSOR OR PRESSURE SWITCH AND GOES BACK NEAR THE CABLE ENTRY OF 220 VLTS. THE THEME IS THAT I DID NOT FIND WHERE IT IS SHORT TO ASSEMBLE AGAIN (the cable was cut while manipulating to change the belt and clean the water pump, with the top cover removed to access from there) THANK HIS COLLABORATION
lusangor
lusangor
56.366
hace 6 años
hace 6 años
Hello Here you have a diagram Luck
ELOKODELASKOLINAS
hace 6 años

MR LUSANGOR, please could you send me this graphic as a file to download and be able to expand and print and visualize better. Thank you for your attention and collaboration

Responder
lusangor
lusangor
56.366
hace 6 años

Click on the photo with the right button of the mouse, then on the image, as a file, I will try it, I will not promise anything

Responder
ELOKODELASKOLINAS
hace 6 años

THANK YOU, MATTER SOLVED

Responder
lusangor
lusangor
56.366
hace 6 años

I'm glad, if you comment the solution would be perfect, so you contribute to the forum. regards

Responder
ELOKODELASKOLINAS
hace 6 años

THE SOLUTION WAS TO IDENTIFY THE CABLE (with the wiring diagram) AND JOIN THE EXTREMES. THANK YOU.

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?