Excellent 6.06 Blue G

Drean Blue 6.06 Titlan Lights

trainertester
hace 6 años
hace 6 años
The entire normal cycle ends, the blue led light comes to an end and what catches my attention is that the lights of the special functions keys are flashing. Is this when the cycle ends or is it indicating something? If I reprogram it, it does any normal washing and again the three lights start to flash at intervals of three in three. nothing is impossible, much less just that I do not remember if the whole cycle has finished apart from the end of program light, the three keys are flashing.
alturasbal
alturasbal
27.174
hace 6 años
hace 6 años
Hello, the error is indicating problems with the water heating resistance, the board detects that the temperature does not increase and acknowledges the error at the end of the wash cycle, error 3 the display or 3 flashes of function LEDs, greetings.
trainertester
hace 6 años

Mr, I said a thousand thanks for answering, I had noticed the error codes and I knew it was problems with the resistance, which is not short
That's why I stayed calm, what caught my attention that the error would accuse once the washing process was finished, (echo or rapid washing) I tested it in those two cycles. Now it affects the operation or is it simply marking the error and can it be used without major inconveniences?

Responder
sys32s
sys32s
341
hace 6 años

Use them in cold water washes ...
If you put washed at 40 60 degrees ..
You will get the error ..

Responder
sys32s
sys32s
341
hace 6 años

The post is that you put a new and ready resistance ..
You have left ok

Responder
alturasbal
alturasbal
27.174
hace 6 años

You can use it without problems, it will only mark the error at the end of the cycle.

Responder
trainertester
hace 6 años

Thank you all for the answers the problem was how you said. the resistance had a cable cut and simpleviata did not look, half the resistance and I was good I realized when I scheduled a temperature wash and did not reach the resistance run

Responder
sys32s
sys32s
341
hace 6 años

Of ten
Because it is not recommended ..
Wash with a puncture resistance or short.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis