Orbis 315/325 thermocentral, start-up help!

BariMM
BariMM
2
hace 5 años
hace 5 años
Hello community, good morning! I go on to detail my problem, I rent a apartment that I am putting in conditions, it was about 10 years without inhabiting. The heating is with an orbis thermo-central, model 315/325 connected to 6 radiators in god plants, the pressure is with a 7/1 Rowa pump. Finishing the winter the pump broke, the official service told me that it had worked a long time without water, and it was destroyed, I found the float of the locked intermediate tank and the empty tank, change for the same 0KM model, also change the membrane of the low camera. Assemble everything, the pilot lights but the burners never start, the pump starts too. Remove the diaphragm and push the cylinder and the burners started. I think the problem is in the pressure of the system or air in it. Purge the pump as it says in your manual but some air remains in the sight glass. If anyone can guide me on how to purge the system I would appreciate it since I do not quite understand how the whole connection is. I leave a couple of photos of the thermocentral, the intermediate tank I think it is called, the spout of the tank enters the left side of the thermocentral Greetings, and thank you very much!
todito
todito
581
hace 5 años

hello you purged the radiators, they have to have a bleed screw you must open each tap and every exit one by one, so that the pipe pressurizes

Responder
Walter dal farra
hace 5 años
hace 5 años
Hi BARI: As if to begin to change the diaphragm, you took out the venturi cañitos, they carry some orring that goes over the pipe and not in front of them. If you lower the diaphragm holder and start the pump, does the bolt go up and out ???? to purge the central thermos there is a butterfly behind the gas solenoid, check that it has no air. LUCK
BariMM
BariMM
2
hace 5 años
hace 5 años
Thanks for the answers! In the end I had connected the pump to the right haha, I was guided by the position of the capacitor of the first pump and put the second in the same position, what I did not realize was that the address is marked in relief on the back of the bomb, it is seen that the first one had been disassembled and the capacitor remained on the left and I was guided by that. I also had a lot of air in the pipe, so I purged in the boiler with the butterfly mentioned by Walter and the rest of the radiators, I think I already purged everything and it's working 10. Thanks!

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis