Wall boilers

Elexia Confort 24ff de chaffoteaux and maury. 70/80 boot failure.

enriqueigl1964
hace 5 años
hace 5 años
Hi, The boiler stops and gives the sporadic misfire. pilots 70 80. If the reset is pressed, it sometimes starts, and sometimes it does not, it is necessary to reset again. When it starts it rises in temperature and stops. When restarting it normally re-ignites, but sometimes, it crashes and gives error. The complete control board has been changed, gas inlet valves, number 7 of the installer manual, gas part consisting of: one electro regulation valve and two safety electro valves have been changed. An installer has come and in the end he has given up. It does not seem to be wiring, since it starts, it starts a lot and stops, and in one of those stops, it blocks. I have noticed that the cycle of starting / stopping by rise / arrival in temperature does it much more often, if this can be a clue. Thanks to those who will contribute ideas / clues / solutions ... Greetings
enriqueigl1964
hace 5 años

the spark is almost always made ... it is as if the gas fails, but the 3 valves have been changed, and the boiler control motherboard ....... and checked that gas enters! It is a mistake that is not understood, unless there is something else that escapes us!

Responder
Calemdq
Calemdq
23.097
hace 5 años

Hello, have you changed the temperature probe (or thermistor)? it seems that it is marking the plate a high temperature and that is why it blocks; It usually happens in the Ariston, which are from the same factory as your boiler, they only change the brand.

Responder
Walter dal farra
hace 5 años
hace 5 años
Hello, Enrique: Did they try to light a match while it sparkles, to know if gas comes out or not? Did they measure that I got to the gas valve? Are the electrodes well placed? LUCK
enriqueigl1964
hace 5 años

The valves have been changed, plate has been changed! tension reaches
the valves like it starts when it wants and when it doesn't, it locks .. Now it starts to give another fault, which is 40 60 80, and it doesn't spark. It usually starts with hot water almost always, but with heating it blocks more often ... It resets and starts, but the heating cycle makes it very fast ... In the end I will think it is something of a probe ...

Responder
Walter dal farra
hace 5 años

The 40 60 80 is a problem of vaccination of gaces, they performed it clean of the fan and verified that it turns well ??? also made him clean of the exchanger ??? They checked tirage ???
LUCK

Responder
enriqueigl1964
hace 5 años

Excuse me Problem solved. it turns out that it was a motherboard failure, but also, the character that presented me at home to repair, did not do well and even having changed plate for another to which I had to undo and re-solder the plate potentiometer old, I damaged a probe connector and continued to fail, until I discovered the connector. It works again without problem since then .... Thanks for help ....

Responder
enriqueigl1964
hace 5 años
hace 5 años
Thanks, I will check with the technician as soon as he comes again ...!
enriqueigl1964
hace 5 años

Good to everyone. To serve all. The boiler already works. The initial fault was motherboard and became a cluster of failures caused, and not detected, by the technician, between wiring probes to the same wrong board, the board itself, a fuse, the start-up switch that I had to solder the other damaged plate, and solder on the one that brought the 3rd, false contacts in plug, when plugging / unplugging, did not check with tester. I didn't blame him, but I doubt his professionalism, since half of the work / fault detection / repair / welding was mine.

Responder
enriqueigl1964
hace 5 años

Likewise, from experience, it is: 1- motherboard failure. changing it to the correct and new model is essential 2- When disassembling, check that all plugs, plug bases, cables are well, correctly interlocked in the bases, that nothing is loose. 3-If you use something of 2nd hand you have to check fuses, connections, plugs, etc ... The tester is the tool to always keep in mind and use. It was not my case, just take out mine, when I saw that I was going to stay again for a weekend without heating and hot water, we had been 2 weeks ...

Responder
enriqueigl1964
hace 5 años

The strangest thing is that I had to desolder and solder the switch from one plate to another, because he did not know / dared to do it ... My was going to be left with a plate that was not going well, because that switch failed, in the which were not checked neither fuses, nor connectors and we had 2 weeks and 3 visits of the technician between 3 and five hours, and 2 other similar plates but that did not go either (for failures of connections of probes and valves ....! ). In the end, I found the solution when using the tester. I ate it for what was served, according to the man, which cost me € 360!

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis