Wall boilers

Peisa DUO does not light, does not spark and temperature at 96 (someti

MrTynKyn
hace 5 años
hace 5 años
Hi. I have a peisa duo boiler. When the 96 mark is off on the display, when I try to turn on (opening the water or the heating) the 23 mark display. However, I do not have a spark and it does not turn on either. I have gas and water in the sockets Any ideas where to start reviewing? Thank you
MrTynKyn
hace 5 años

Update: Unplug the boiler for a while and start at its normal temperature (sanitary).
Where should I start? Buy an NTC temperature sensor (from the pipe measure), change it and monitor that the sanitary temperature is stable?

Responder
Calemdq
Calemdq
23.097
hace 5 años

Hi
What model exactly is the Peisa? with forced throw, with natural shot ?? Please indicate this detail as it depends on the model is what error 96 indicates,
Regards !

Responder
MrTynKyn
hace 5 años

It is forced shooting. The model is DIVA DUO.

Responder
Calemdq
Calemdq
23.097
hace 5 años
hace 5 años
OK, now if I can suggest something to you: start by doing a good cleaning of the circulation system, you have to disassemble the fume hood, turbine, clean everything, remove the lint and accumulated dirt; verify that the smoke pressure switch acts normally, that the venturi is not clogged or cracked. If the forced draft does not operate correctly, the boiler will never ignite. Regards !
MrTynKyn
hace 5 años

Thank you ! . Yesterday I unplugged it while I search and learn. At the time the plug and began to work (the display returned to normal temperature)
Your suggestion is still the part of smoke taking into account what he did? (I had been inclined to the NTC sensor temperature of the sanitary circuit).

Responder
Calemdq
Calemdq
23.097
hace 5 años

What it tells you before the start is an error that according to your model corresponds to the fact that it does not start the ignition chain due to a smoke evacuation failure

Responder
MrTynKyn
hace 5 años
hace 5 años
Thank you very much, I will be disassembling and cleaning what you advise me. I have the user manual of this boiler that is very basic. Can you get a more technical manual with your fault codes?
MrTynKyn
hace 5 años

Sorry for not commenting on the solution. It was the temperature sensor of the heating circuit. It was broken and marked wrong temperatures. When it broke at all, he gave the error, take it out and change it was the solution
Thank you

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis