Hello, install a thermostat peisa h21100 in boiler peisa duo diva but I don't know if it's ok. I tested the boiler link cables and the blue one had the polarity so that connect according to the manual in 1 of the thermostat and brown in 2. I wanted to know if it is ok since the thermostat marks the ambient temperature at 24 and I programmed it at 20 And it will not cut. I appreciate the help
Walter Molina
hace 5 años

Insurance? Because the manual says 1 and 2.

Responder
Walter Molina
hace 5 años

You left me ice cream, should I think I bought something trout? In short, I thank you for your time and knowledge, you are a boss
A million thanks !!

Responder
Calemdq
Calemdq
23.097
hace 5 años

In Peisa everything can happen, that they were wrong in the packaging or that they used old brochures, inside all that thermostat is going well, the only one against it is that the battery dies without warning, and that usually happens in winter when it is cold , but hey, he changes and keeps walking, Regards !!

Responder
Calemdq
Calemdq
23.097
hace 5 años
hace 5 años
Hi If you programmed at 20 and the current one is 24 until the temperature drops, the boiler will not turn on. The connection of this thermostat is very simple, from terminals 1 and 3 you have to bring 2 direct wires to the boiler, they have no polarity, it acts as a switch Regards !
Walter Molina
hace 5 años

Very clear only that the boiler does not stop, that is, I put the thermostat at 20, it marks me that the ambient temperature is 24 and still does not stop. Thanks for answering

Responder
Calemdq
Calemdq
23.097
hace 5 años

And if you disconnect a wire from the thermostat cut the boiler?

Responder
Walter Molina
hace 5 años

Yes, if I disconnect one cuts. I connected the cables as the manual says, on terminals 1 and 2

Responder
Calemdq
Calemdq
23.097
hace 5 años

No no, they go in 1 and 3 !!

Responder
Walter Molina
hace 5 años

Insurance? Because the manual says 1 and 2. I will try it anyway

Responder
Calemdq
Calemdq
23.097
hace 5 años

If I remember correctly they go at the ends, the middle one does not connect, and number 1,2,3 from the bottom up, look and comment

Responder
Walter Molina
hace 5 años

Try to send a picture of what the manual says. Anyway I connected it as you told me and the boiler turns on and off. I did the test by raising the temperature or lowering it on the thermostat. I assume that if it turns on or cuts according to the temperature it is because it is well connected.

Responder
Walter Molina
hace 5 años
hace 5 años
1518485013416-12012159.jpg [1.15MB] Try to send a picture of what the manual says. Anyway I connected it as you told me and the boiler turns on and off. I did the test by raising the temperature or lowering it on the thermostat. I assume that if it turns on or cuts according to the temperature it is because it is well connected.
Calemdq
Calemdq
23.097
hace 5 años

Well, you have sown the question and I went to my files, the manual you have is incorrect, I went to the manuals section of this forum https://yoreparo.com/calefaccion/calderas-murales/manuales/ the correct manual. And it was as I said, so bad I do not walk from memory! Greetings, I'm glad you solved the problem, rate answers or close the question so the solution is registered

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis