Pressure loss boiler gas condensation

Pepe2
Pepe2
4
hace 5 años
hace 5 años
VIESSMANN Vitodens 100-35 A few hours ago (about three) the expansion vessel was replaced. The pressure, already adjusted, has dropped from 1.5 to 1.2. (before it fell to 0 in twelve hours or less). I have checked the water meter: it does not move, nor has it moved in that time. Can, despite this, exist enough leakage to lower the pressure? . From how much water loss pressure drop occurs). Thanks in advance I reduce the question to the following: What damage can occur in the boiler by working at a pressure of only 1 versus 1.5? Closing keys I have isolated the boiler circuit, resetting the pressure again to 1.5: after about 24 hours it has only dropped to 1.4. I deduce that the circuit has been well purged and that the pressure loss is probably due to the heating circuit. (As I said at the beginning, the accountant of water does not manifest losses). Should I focus on radiators? On the other hand, if at lower pressure less wear and, as I imagine, what flow or temperature will depend on it, what would be the optimum pressure? The one recommended by the manufacturer? Thank you so much for the comments . They are giving me ideas to form a criterion.
Calemdq
Calemdq
23.097
hace 5 años

Damage none ... on the contrary, if the pressure is low the whole set will work relieved and the duration of the materials will be longer, the boiler with 0.7 bar already works normally, which is the pressure necessary for the pump to circulate the water through the pipe, less than that pressure means that water is missing in the circuit

Responder
Calemdq
Calemdq
23.097
hace 5 años
hace 5 años
Hi After changing the glass, did they completely purge the circuit? if there is air, it causes pressure fluctuations as described regards !
Pepe2
Pepe2
4
hace 5 años

I'm not sure ... I remember something like a tube connected to a boiler point to drain water? Purge?...
At 24 hours it had dropped to 1. At that time, readjust to 1.5 again. Two days have passed and this time it went down to 1.2. I suspect that the reason is what you say.

Responder
Calemdq
Calemdq
23.097
hace 5 años

to purge properly, it is best to go through all the radiators and remove the air one by one

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis