hace 8 años
por lo general no alimenta papel del adf, porque el scaner esta sucio, opticos o lamparas, primero que todo deves de limpiar bien todo el sistema y de ahi ajustar
Main
code Sub
code Contents Details of function/operation
41 06
OC cover float detection
level adjustment [Function]
When this simulation is executed, the current set value is displayed. When [ENTER]/[START]
key is pressed, the mirror base unit moves to the SPF/RSPF scan position to acquire the OC
cover float detection level.
When the mirror base unit returns to the home position, the acquired value is displayed.
If the adjustment is NG, the following message is displayed.
AL-2030/2040CS: Misfeed lamp lights up, and the 7seg display remains unchanged.
AL-2050CS: The LCD indicates "ERR."
Note that, this simulation must be executed with the OC cover closed.
• If the value is 0, float detection is not performed in normal jobs.
[Operation] (AL-2050CS only)
1) Initial display <Canceling - when [Clear]/[Clear All] key is pressed->
41-06 OC FLOAT LEVEL
0 After canceling, the machine goes into the sub code entry
standby mode.
2) [ENTER/START] key
41-06 OC FLOAT LEVEL
EXECUTING... THE JOB IS BEING
CANCELED.
3) When the level is acquired:
41-06 OC FLOAT LEVEL
**** OK
3) When the level is not acquired:
41-06 OC FLOAT LEVEL
**** ERR