hace 10 años
Esta es toda la información del manual para cargar el firmware desde un pendrive. Asegurate de ponerlo en el slot correcto. Y sigue todos y cada uno de los pasos.
*#* Recuerdo que esto es una guia, ninguno nos hacemos responsables de lo que pueda ocurrir por un mal uso *#*
Espero noticias. Suerte.
Saludos
USB memory
7.2.1 Preparation
• Conditions for USB memory which can be used for updating the firmware are as follows:
- Without security function added (security function can be turned off)
- Memory with 1 GB to 2 GB are recommended (One with 4 GB or more may not operate)
- Corresponds to USB2.0
- Formatted with FAT32 type
7.2.2 Procedure
1. Connect the USB to the PC, and copy the firmware data to the USB memory.
NOTE
• The firmware data to be updated must be copied to the root directory with the file
name “A0P0FW. tar.”
• More than one firmware data with a single model or multiple models can be stored
in the USB memory. (Maximum of fifteen files)
When storing more than one firmware data, make a folder with a name “(model
code) FW” (“A0P0FW” for this machine) right under the root directory.
(File names can be set arbitrarily)
• When making a folder and storing more than one firmware data, it is also necessary
to copy the firmware data “A0P0FW. tar” to the root directly.
2. Turn OFF the main power switch and the sub power switch.
3. Remove the screw [1].
4. Loosen the screw [2], and lift up the cover [3] of the USB port.
5. Insert the USB memory device to the USB port [4] for service.
NOTE
• USB memory must be connected with the main power switch/sub power switch
off.
• When updating the firmware, use the USB port for the service.
It cannot be updated when connected to another USB port.
6. Turn ON the main power switch and the sub power switch.
7. Control panel shows F/W items to be updated, and select the particular type of F/W to
be updated. (Select [YES].)
NOTE
• Unless one of the keys on the control panel is pressed, firmware is automatically
updated after 30 seconds when the main power switch/sub power switch is turned
on.
• When the BootRom file is in the firmware data, [RootRom] key is displayed. Pressing
the key updates data.
• When more than one firmware are stored in step 1, pressing [FW Data Select]
enables selection. (Data of other models cannot be selected.)
(Data with * at the left top of data selection screen will be the default data copied to
the root directly in the USB memory.)
8. Press the [START]. (At this time, the Start key starts blinking red.)
9. Check that the control panel shows the message indicating that the data has been
rewritten correctly ([Downloading Completed]). Check also the check sum value
([Check Sum ####]) shown on the control panel. (The Start key lights blue.)
10. Turn OFF the main power switch and the sub power switch.
11. Remove the USB memory device, and fix the cover of the USB port using a screw.
12. Turn ON the main power switch and the sub power switch.
NOTE
• When turning the main power switch ON for the first time after the firmware is
updated, data may sometimes be internally updated.
In that case, the following message will be displayed. Never turn the main power
switch OFF until either the serial number input screen or the trouble code screen
is displayed.
13. Call the Service Mode to the screen.
14. Select [Firmware Version].
15. Make sure if the version of firmware is updated.