te paso el detalle de la falla:
322 D Synchronization error
The synchronization signal was not
issued within 500 ms after the LD fired
while the polygon motor was turning at
the prescribed number of revolutions.
• Laser synchronization board
connectors loose, disconnected, or
damaged
• Laser synchronization board
defective
• LD drive board defective
ESTA LISTA TE DICE LA FALLA Y LA POSIBLE SOLUCION:
SC 322 Laser Sync Detect error - check harness and connections between LD unit and BICU
SC 322 Laser Sync Detect error - check for 5vdc at CN403-3, replace 5 VDC door switches as needed
SC 322 Laser Sync Detect error - replace laser sync detect board
SC 322 Laser Sync Detect error - replace laser unit
SC 322 Laser Sync Detect error - replace BICU
SC 322 Laser Sync Detect error - excess toner dust inside laser blocking beam, clean LD unit
SC 322 Laser Sync Detect error - Laser synchronization board connectors loose, disconnected, or damaged
SC 322 Laser Sync Detect error - Laser synchronization board defective
SC 322 Laser Sync Detect error - LD drive board defective
SC 322 Laser Sync Detect error - do in order: SP2-109-8, SP2-109-3, SP2-109-4